In North America, this option has a decal [A] attached that says 110V-130V. Peel off this decal.
- Install the heater board. (Heater board Installation)
- Pull out the first and second paper feed trays.
- Connect the harness of the tray heater [A] for the main unit to the socket in the inner rear frame of the main unit (
x1).
- Insert the tabs of the tray heater for the main unit in the cutouts in the inner rear frame of the main unit, and then attach the heater (
x1).
- Reattach all the paper feed trays, covers, etc. which have been taken off.
Do the following two steps to set the Anti-Condensation Heater to be constantly ON.
- Set the setting of SP5-805-001 (Anti-Condensation Heater ON/OFF setting) to [1].
Manually disconnect the PCU and scanner heaters.
- The PCU and scanner heaters must be disabled because the temperature in the machine could become too high, causing problems with toner clogging, or damage to the scanner lamp stabilizer.