In North America, this option has a decal [A] attached that says 110V-130V. Peel off this decal.

  1. Install the heater board. (Heater board Installation)
  2. Pull out the first and second paper feed trays.
  3. Connect the harness of the tray heater [A] for the main unit to the socket in the inner rear frame of the main unit (x1).
  4. Insert the tabs of the tray heater for the main unit in the cutouts in the inner rear frame of the main unit, and then attach the heater (x1).
  5. Reattach all the paper feed trays, covers, etc. which have been taken off.

Do the following two steps to set the Anti-Condensation Heater to be constantly ON.

  1. Set the setting of SP5-805-001 (Anti-Condensation Heater ON/OFF setting) to [1].
  2. Manually disconnect the PCU and scanner heaters.

    • The PCU and scanner heaters must be disabled because the temperature in the machine could become too high, causing problems with toner clogging, or damage to the scanner lamp stabilizer.