SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC302-00 | D | High Voltage Power Source: Charge: Output Error |
The machine detects the error detection signal “L (unexpected)” 10 times for 200 msec consecutively when monitoring the error signal every 20 msec during outputting the PWM signal. | ||
Hardware error
Load error
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC324-01 | D | Development Motor: Bk: Lock |
Lock signals are observed at 2 sec intervals during motor ON, and a High level is detected at least 20 times. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC360-01 | D | TD Sensor Adjustment Error |
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC361-01 | D | TD Sensor Output Error: Upper Limit (K) |
The following condition continuously exceeds the upper limit threshold value (SP3-211-003).
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC362-01 | D | TD Sensor Output Error: Lower limit (K) |
TD sensor output: Vt (SP3-210-001) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005) | ||
TD sensor connector missing/dropout | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC370-00 | C | ID Sensor Calibration Error |
Regular reflection optical output voltage of the ID sensor: Vsg_reg cannot be adjusted to within target range. Upper limit (SP3-320-013: initial value 4.5V) Lower limit (SP3-320-014: initial value 3.5V) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC391-00 | D | High Voltage Power Source: Development : Output Error |
When the machine detects the error detection signal “L (abnormal)” 10 times for 200 ms consecutively by monitoring the error detection signal every 20ms during output of the PWM signal used as an error detection target. | ||
Hardware error
Load error
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC396-01 | D | Drum Motor Lock |
Lock signals are observed at 2 sec intervals during motor ON, and a High level is detected at least 20 times. | ||
| ||
|