- Before replacing the cleaning blade, set SP3-701-009 to “1” and turn the main power switch OFF.
- If you have to turn the power on again before replacing the part, execute the SP again before replacing the part.
- After replacing the cleaning blade, turn the main power switch ON.
- Remove the PCU. (PCU/Development Unit)
- Remove the OPC drum. (OPC Drum)
- Remove the charge roller and cleaning roller. (Charge Roller, Cleaning Roller)
Remove the cleaning blade [A]. (
x2)
- The cleaning blade [A] has two different types of holes: a circle (
), and an oval (
). Remove the screw on the circle side first, and then, remove the oval side.
- The cleaning blade [A] has two different types of holes: a circle (