When you replace the PM parts, you need to reset the PM counter manually.
There are two ways to reset the PM counter for this machine.

  • Method 1: Reset by SP3-701 (Manual New Unit Set). This is the conventional method.
  • Method 2: Reset by [PM Counter / New Unit Set] Menu.

"Method 2" is recommended for its ease of operation.

  • For the following units, there is a new unit detection mechanism. It is not necessary to reset PM counters.
    - Fusing unit
    - PCDU
    - Waste Toner Bottle (When the machine stopped because the waste toner bottle was full)

  • If you only replace the development unit (not replacing the PCU), the PCU counter will not be cleared when you set SP3-701-023 (Manual New Unit Set: Development Unit) in advance.

  • Toner recycling mode is disabled by default.