1. Enter the SP mode.
  2. Output the SMC logging data with SP5-990-004.
    Make sure to shut down and reboot the machine once before printing the SMC. Otherwise, the latest settings may not be collected when the SMC is printed.
  3. Set the following SPs (New Unit Detection) to "1".

    Item

    SP

    PCU

    PCU: SP3-701-002

    Cleaning Blade: SP3-701-009

    Charge Roller: SP3-701-018

    Cleaner: Charge Roller (Cleaning Roller): SP3-701-019

    OPC: SP3-701-021

    Separation Pawl (Pick-off Pawls): SP3-701-022

    Development Unit

    Development Unit: SP3-701-023

    Development (Developer): SP3-701-024

    Development Filter: SP3-701-025

    Bearings: Development Screw (Development Mixing Auger Bearings): SP3-701-028

    PTR (Paper Transfer) Unit

    SP3-701-108

    Fusing Unit

    Fusing Unit: SP3-701-115

    Fusing Belt (Heating Sleeve Belt Unit): SP3-701-116

    Pressure Roller: SP3-701-118

    Pressure Roller Bearings: SP3-701-119

    Waste Toner Bottle

    (When the bottle is replaced before the machine detects bottle full and stops)

    SP3-701-142

    ADF

    ADF: Pick-up Roller: SP3-701-206

    ADF: Feeding Belt: SP3-701-207

    ADF: Reverse Roller: SP3-701-208

  4. Turn the main power switch OFF, and disconnect the power cord from the outlet.
  5. Replace the PM parts and turn the main power ON.
    The machine will reset the PM counters automatically. In the case of the development unit, developer initialization will also be done automatically.
  6. Exit the SP mode.