• Unplug the machine power cord before starting the following procedure.

  1. Install the stepped screws (× 2).
  2. Install the feeler guide [A].

  3. Install the platen cover [A].
  4. Place the platen sheet [A] on the exposure glass.
  5. Line up the rear left corner of the platen sheet flush against corner [B] on the exposure glass.
  6. Close the platen cover.
  7. Open the platen cover.
  8. Press the surface of the platen sheet gently to fix it on the platen cover securely.
  9. Connect the power cord and turn on the main power.