• Set SP3-701-116 to “1” and turn the main power OFF before replacing.
  • If you have to turn the power on again before replacing the part, execute the SP again before replacing the part.
  • After replacing the unit, turn the main power ON.

  • To clear SC544-02 or SC554-02, replace the fusing unit or install a fuse (provided in the heating sleeve belt unit) in the fusing unit.
  • When clearing SC544-02 or SC554-02 by installing a fuse (provided in the heating sleeve belt unit) in the fusing unit, see To Clear SC544-02 or SC554-02.
  • The new unit detection fuse packed with the heating sleeve belt unit is used to cancel SC544-02/554-02. Discard the fuse if these SCs did not occur.
  • When replacing the heating sleeve belt unit at EM replacement, installing a fuse is not necessary. Do not use the fuse for EM replacement.