SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC440-00 | D | High Voltage Power Source: Paper Transfer : Output Error |
The machine detects the error detection signal “L (unexpected)” 10 times for 200 msec consecutively when monitoring the error signal every 20 msec during outputting the PWM signal. | ||
Hardware error
Load error
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC452-00 | D | Transfer Roller Contact Motor Error |
When the machine does not detect the high/low signal for a specified time after the transfer roller contact motor has been turned on. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC460-00 | D | High Voltage Power Source: Separation : Output Error |
The machine detects the error detection signal “L (unexpected)” 10 times for 200 msec consecutively when monitoring the error signal every 20 msec during outputting the PWM signal. | ||
Hardware error
Load error
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC497-00 | C | Machine Temperature Detection Thermistor Error |
The output of the temperature sensor is out of the following range.
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC498-00 | C | Temperature and Humidity Sensor Error (Main machine) |
The output of the temperature/humidity sensor is out of the following range.
| ||
| ||
|