The result is presented in 8 digit numbers. Using 2 digits for each color, the result appears in the order of Y, M, C, and K from the left.
The detection results of each sensor are saved (The latest 10 detection results)
- SP3-012-001 to 010 (Front)
- SP3-012-011 to 020 (Center)
- SP3-012-021 to 030 (Rear)
Category | Code | Result name | Description |
---|---|---|---|
00 and larger | 00 | Not executed | Factory default setting(SP default) |
10and larger Result (Normal) | 11 | Succeeded | - |
40 and larger ID Sensor | 41 | ID Sensor Output error (Max) | Vt>Max |
42 | ID Sensor Output error (Min) | Vt<Min | |
43 | ID Sensor error (Max) | Development gamma is in target, but Vt value is less than upper limit. | |
44 | ID Sensor error (Min) | Development gamma is in target, but Vt value is less than lower limit. | |
45 and larger ID Pattern detection | 45 | ID Pattern extract error | Cannot detect ID Pattern |
50 | Vmin_Bk/K2 error(Max) | K:Vmin_Bk / CMY:K2>Max | |
51 | Vmin_Bk/K2 error(Min) | K:Vmin_Bk / CMY:K2<Min | |
52 | K5 error (Max) | K5>Max | |
53 | K5 error (Min) | K5<Min | |
54 | K5 calculated approximate point error | K5 calculated approximate point <Min | |
55 | Development gamma error (Max) | Development gamma >Max | |
56 | Development gamma error (Min) | Development gamma <Min | |
57 | Start developing voltage: Vk error(Max) | Start developing voltage: Vk>Max | |
58 | Start developing voltage: Vk error(Min) | Start developing voltage: Vk<Min | |
59 | Not enough valid data | Adhesion amount data for development gamma calculation point is under 2 | |
90 and larger Result(End) | 90 | Potential not adjusted | Potential control method is set as [0:FIX] |
99 | Stopped | Stopped by door open, power off, error. (Set when execute.) |
- Execution result example (In order of YMCK from left)
- Factory default (SP default): [00,00,00,00]
- Starting adjust: [99,99,99,99]
- Fail Vsg adjust(Y): [21,99,99,99]
- Error of Development gamma Max(C): [99,99,55,99]
- Succeeded: [11,11,11,11]