Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps.
- Check if all connectors related to TM/ID sensor are connected securely. Reconnect the connectors if they are disconnected, or loose.
- If TM/ID sensor is contaminated, clean it with a damp cloth (never use a dry cloth or alcohol).
Check if there is an abnormality on the image transfer belt surface. - If any abnormalities are found on the image transfer belt surface, replace the image transfer belt.
- Belt scratched
- Belt corrugation, belt skew
- Cleaning failure
- Background stains
- Filming
- Check the TM/ID sensor for malfunctions, and repair or replace it if there are any defects.
- Check the harness. Replace the harness if it is damaged; connect it if it is disconnected.
- If the SC is not cleared even after performing steps 1 to 5, replace the BCU.