1. Perform Steps 1 to 6 of "Connecting to Main Machine Tray" (Connecting to Main Machine Tray).
  2. Pull out the 1st and 2nd paper feed trays of the 2-tray paper feed unit.
  3. Pass the harness of the heater [A] out through the hole in the inner rear frame of the 2-tray paper feed unit, and then attach the tray heater on the bottom plate (x1).
  4. Remove the securing brackets [A] of the 2-tray paper feed unit.
  5. Remove the rear cover [A] of the 2-tray paper feed unit.
  6. Remove the bracket [A] on the bottom of the main unit (x1).
    The removed bracket can be discarded.
  7. Connect the PFU harness [A] of the 2-tray paper feed unit to the relay harness [B] of the main unit and the heater harness [C] (x4).
  8. Reinstall the removed parts and covers.
  9. Connect the power supply cord and turn ON the main power.
  10.  To keep the anti-condensation heater constantly ON, set SP5-805-001 (Anti-Condensation Heater ON/OFF setting) to "1".