There are two ways to reset the PM counter for this machine.
"Method 2 By [PM Counter / New Unit Set] Menu" is recommended for its ease of operation.
- After the PM counter for the fusing sleeve belt unit reaches its PM life (430K pages or 313,153,000 mm), the machine stops automatically. Replace the fusing sleeve belt unit before the machine stops (stop warning: 415K pages or 302,229,000 mm, stop: 430K pages or 313,153,000 mm).
- For the following units, there is a new unit detection mechanism. It is not necessary to set the new detection flag with SP3-701 (Manual New Unit Set).
- Fusing unit as a complete unit
- PCDU as a complete unit
- Waste Toner Bottle (When the machine stopped because the waste toner bottle was full)
SP descriptions
- SP3-701 (Manual New Unit Set)
Enables/disables the new unit detection function.
When this function is ON, the machine automatically resets the PM counter when a new unit is detected.