• Do not touch the rollers but hold the upper/lower resin parts [A] when you lift the Image Transfer Unit. Touching the rollers may cause poor image quality.

  1. Remove the image transfer belt unit. (Image Transfer Belt Unit)
  2. Remove the image transfer front cover and image transfer top cover. (Image Transfer Front Cover, Image Transfer Top Cover)
  3. Remove the bracket [A].
  4. Remove the brackets [A] [B].
  5. Remove the image transfer cleaning unit. (Image Transfer Cleaning Unit)
  6. Remove the tension fixing frames [A] and [B] (front side: black, rear side: gray).
  7. Take out the stand [A] from its storage location [B] in the front cover, and attach it to the front of the image transfer belt unit.
    The stand [A] is used to stand the image transfer belt unit on its side.
  8. Position the image transfer unit with the stand underneath.
  9. Rotate the gear [A] to change to the OPEN position.
    The part in the red circle opens.
  10. Release the tension, and remove the belt.