After performing recovery for SC370, execute the following adjustment procedure.
- Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
- Execute the following SPs and check the results:
- SP2-194-007 (Execution Result)
- SP2-194-010 (Error Result: C)
- SP2-194-011 (Error Result: M)
- SP2-194-012 (Error Result: Y)
Execution result examples
Factory default: 0
Success: 1
- Execute SP3-011-001 (Manual ProCon :Exe).
- Execute the following SPs and check the results.
- SP3-012-001 to 010 (Front)
- SP3-012-011 to 020 (Center)
- SP3-012-021 to 030 (Rear)
Execution result examples (in order of YMCK from left)- Factory default: [00,00,00,00]
- Starting adjust: [99,99,99,99]
- Fail Vsg adjust (Y): [21,99,99,99]
- Error of Development gamma Max (C): [99,99,55,99]
- Success: [11,11,11,11]