SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC561-01 | A | Pressure Roller Thermistor (Center) Disconnection |
SC561-05 | D | Pressure Roller Thermistor (Center) Disconnection (Low Power) |
Below 0 degree C is detected for 20 sec. continuously. Detection period: 100 ms, detection frequency: 10 times or more. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC562-02 | A | Pressure Roller Thermistor (Center) Does Not Reload |
Does not reach 40 degree C after fusing lamp 1ON for 12 sec. | ||
SC562-05 | D | Pressure Roller Thermistor (Center) Does Not Reload (Low Power) |
- | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC563-00 | A | Pressure Roller Thermistor (Center) High Temperature Detection (software) |
Above 230 degrees C detected for 1sec. continuously. Detection period: 100ms, detection count: 10 times or more. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC564-00 | A | Pressure Roller Thermistor (Center) High Temperature Detection (hardware) |
Above 240 degrees C detected | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC569-00 | D | Paper Exit/ Pressure Release Motor Error Detection |
Retry operation fails 3 times consecutively. | ||
| ||
Inspect the pressure roller HP sensor with SP5-803-047. If there is no response from the sensor, perform steps 1 and 2.
|