• SP7-621 (PM Counter Display: Paper)
    Displays the number of sheets printed for each current unit.
    When a unit is replaced, the machine automatically detects that the new unit is installed.
    Then, the current PM counter value is automatically moved to the PM Counter – Previous (SP7-906-1 to 10) and is reset to "0".
  • SP7-625 (Previous Unit Counter: Pages)
    Displays the number of sheets printed for the previous unit.
  • SP7-906 (Previous Unit Counter:Distance)
    Displays the rotation distance of the previous drum.
  • SP7-944 (PM Counter Display: Distance)
    Displays the rotation distance of the current drum.
  • SP7-853 (Replace Counter)
    Displays the number of times each PM part has been replaced.
  • SP7-950 (Unit Replacement Date)
    Displays the replacement date of each PM unit.
  • SP5-990 (SP Print Mode)
    Prints the configuration sheets of the system and user settings : SMC.
    Make sure to shut down and reboot the machine once before printing the SMC. Otherwise, the latest settings may not be collected when the SMC is printed.