SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC441-00

D

PCU: Black / ITB Drive Motor: Lock

Motor status is observed at 100ms intervals during motor ON, and the unlock status is detected at least 20 times.

  • Motor defective
  • Connector disconnected
  • Harness broken
  • IOB defective
  • Unit torque increased.
  • Replace the motor
  • Reconnect the connector
  • Replace the harness
  • Replace the Imaging IOB.
  • Check the load on the motor (PCDU, Image transfer unit, Paper transfer unit, Waste toner bottle).
  • Replace the PCDU, Image transfer unit, Paper transfer unit or Waste toner bottle.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC442-00

D

ITB Lift Error

Even though the ITB lift motor (also Toner supply motor (M)) rotates, the ITB lift sensor failed to detect the specified sensor feeler status within specified time.

  • Contact/separation operation: If not detected in 2000msec
  • Home position operation: If not detected in 5000msec

Signal detection sampling period: 10msec

  • Image transfer unit not set/faulty setting
  • Sensor dirt
  • Sensor defective
  • Motor defective
  • Unit load large
  1. Reset the image transfer unit properly.
  2. Clean the ITB lift sensor
  3. Check the harness (disconnected, loose connectors)
  4. Replace the ITB lift sensor
  5. Replace the image transfer unit
  6. Replace the contact/separation drive unit

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC452-00

D

Paper transfer contact motor error

Paper transfer contact motor: position sensor cannot detect the sensor filler state within the predetermined time (see below) even if the paper transfer contact motor is rotated.

  • Contact operation: If not detected in 2000msec
  • Home position operation: If not detected in 5000msec

Signal detection sampling period: 10msec

  • Sensor dirt
  • Sensor defection
  • Motor defection
  • Unit load large
  • Replace the contact drive unit
  • Replace the image transfer unit
  • Check the harness

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC491-00

D

High voltage power source: charge/development: output error

SC detection signal (charge/development) is L (abnormal) for 200 ms consecutively during high voltage (charge/development) output.

H/W error

  • Output contact setting fault
  • Controller connector set fault
  • Ground fault of output high voltage path
  • Surface/air clearance insufficient (arc discharge)
  • Controller harness disconnection, short-circuit
  • PCU setting fault
  • Control board _IOB error (related signal error)
  • HVP_CB error

Load error

  • Grounding fault of charging output, short-circuit with other outputs
  • Surface/air clearance insufficient in charging output path (including distance from other outputs)
  • Abnormal deterioration of drum, and over current due to pinholes
  • Drum vs charge roller gap error (PCU error).
  • Over current due to drum surface condensation
  • Grounding fault of developing output, short-circuit with other outputs
  • Surface/air clearance insufficient in developing output path (including distance from other outputs)
  • Other
  
  • Turn the main power OFF/ON.
  • Reset or replace the harness of high voltage power supply feed path
  • Reset or replace the harness between IOB-HVP_CB
  • Replace the PCDU.
  • Check the operation of the contact mechanism
  • Replace the HVP_CB
  • Replace the Imaging IOB.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC492-00

C

High voltage power source: image transfer/paper transfer: output error

SC detection signal (transfer) is L (abnormal) for 200 ms consecutively during high voltage (transfer) output.

H/W error

  • Output power connector setting fault
  • Controller connector setting fault
  • Output high voltage Harness disconnection
  • Controller harness disconnection, short-circuit
  • Transfer unit setting fault
  • Control board_ IOB error (related signal error)
  • HVP_TTS error

Load error

  • Increase in paper transfer roller impedance (low temperature environment/impedance rise/impedance rise due to dirt)
  • Operation fault of paper transfer contact mechanism
  • Increase in image transfer belt impedance
  • Opening in load power supply path
  • Reset or replacement the harness of high voltage power supply feed path
  • Reset or replace the harness between IOB-HVP_TTS
  • Reset or replace the transfer unit
  • Check operation of the contact mechanism
  • Replace the HVP_TTS
  • Replace the Imaging IOB.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC497-00

C

Machine temperature detection thermistor error

Temperature sensor output error: Below 0.56V, or above 3.0V

  • Connector disconnection or broken
  • Sensor (Thermistor) defective

Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Check if all connectors related to the Imaging Temperature Sensor (Thermistor) are connected securely. Reconnect the connectors if they are disconnected, or loose.
  2. Replace the Imaging Temperature Sensor (Thermistor).

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC498-00

C

Temperature and humidity sensor error

Temperature sensor output error: Below 0.76V, or above 2.90V, or Moisture sensor output error: more than 2.4V

  • Sensor not setting (disconnection or broken)
  • Sensor defective

Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.

  1. Check if all connectors related to the Temperature and Humidity Sensor are connected securely. Reconnect the connectors if they are disconnected, or loose.
  2. Replace the Temperature and Humidity Sensor.