- Perform Steps 1 to 6 of "Connecting to Main Machine Tray" (Connecting to Main Machine Tray).
- Pull out the paper feed tray of the 1-tray paper feed unit [A].
- Pass the harness of the heater [A] out through the hole in the inner rear frame of the 1-tray paper feed unit, and then attach the tray heater on the bottom plate using a stubby driver (
x1).
- Pull out the 1st and 2nd paper feed trays of the 2-tray paper feed unit [A].
- Pass the harness of the heater [A] out through the hole in the inner rear frame of the 2-tray paper feed unit, and then attach it (
x1).
- Remove the securing brackets [A] of the 1-tray paper feed unit.
Remove the rear cover [A] of the 1-tray paper feed unit.
- Remove the bracket [A] on the bottom of the main unit (
x1).
The removed bracket can be discarded. - Remove the connector cover [A] on the bottom of the 1-tray paper feed unit.
The removed cover can be discarded. Route and connect the PFU harness as follows;
Connect the connector [A] to the relay harness on the main unit.
The connector [C] will be connected to the heater in step 12.
- Mount the connector [B] on the frame in order to connect it to the 2-tray paper feed unit.
Remove the CTL board.
Tilt the CTL board to the front to expose the connector, and then connect the heater harness.
- Remove the securing brackets [A] of the 2-tray paper feed unit.
- Remove the rear cover [A] of the 2-tray paper feed unit.
- Connect the PFU harness [A] of the 2-tray paper feed unit to the relay harness [B] from the main unit and the heater harness [C] (
x3).
- Reinstall the removed parts and covers.
- Connect the power supply cord and turn ON the main power.
To keep the anti-condensation heater constantly ON, set SP5-805-001 (Anti-Condensation Heater ON/OFF setting) to "1".