• When installing this option, turn OFF the main power and unplug the power cord from the wall socket. If installing without turning OFF the main power, an electric shock or a malfunction may occur.

  • Do not touch the roller surface during replacement. Also, when taking out the unit from the box, be careful not to touch the roller surface [A].

  1. Enter the SP mode.
  2. Set SP2-400-001 (Paper Transfer Roller Settings Width of Paper Transfer Roller) to "1 (1: Wide roller)".

    • When SP2-400-001 is changed over, a message is displayed stating "Switch the power OFF/ON".

  3. After the SP is changed, turn OFF the main power.
  4. Replace the roller [A].
    For details about how to replace the roller, refer to Paper Transfer Roller.

    • During PM replacement, do not install the wrong type of roller.
    • [A]: The standard roller has a gray collar at its end.
    • [B]: Imageable Area Extension Unit Type P11 does not have a collar on it.

  5. Turn ON the main power.
  6. Using SRA3 paper, check that a full-bleed halftone image is output, and that the image extends to 315 mm in width.

SP descriptions

  • SP2-400-001 (Paper Transfer Roller Settings)
    Specifies the width of the Paper Transfer Roller. This SP must be set to"1" when Imageable Area Extension Unit Type M19 is installed.
    0: Default roller
    1: Wide roller