When both Paper Feed Unit PB3250 [A] and Paper Feed Unit PB3240 [B] are connected, it is necessary to route the heater harness between the paper feed units.

 

Order the following parts [A], [B] and [C] as service parts.

 No.

Description

Q’ty

Remarks

[A]1 : Tray heater for optional PFU/LCIT1Parts from Anti-Condensation Heater for Optional PFU and LCIT*
2 : Tapping screw with washer : M4 x 101
[B]Five-tier paper tray harness1

Harness for Five-tier Paper Tray

[C]



 

 

 

 

1: PCB: DHB1Electrical Components*


2: Tapping screw: M3 x 6

3

3: Harness between HDB and PSU (Black)

1

4: Harness between HDB and PSU  (Gray)

1

5: Harness for tray

1

*The voltage varies between different regions, so a set of the electrical components and the tray heater (120V and 230V) is available for each region. Order the correct set for your region.


Connection schematic diagram

[A]: DHB