When the abnormal noise is coming from the fusing unit, work through the following flow chart, and check whether the fusing unit is the cause, by using SP1-158 (Abnormal Noise Confirmation).

If the fusing unit is the cause, replace the fusing unit. If the drive module is the cause, in addition perform the operation check of various motors by using output checks, to identify which motor is the cause.

Related SPs

SP No.SP NameFunctionDescription

SP1-158-001

Abnormal Noise Confirmation: Unit: Execute

The fusing motor rotates with the heating control.

Fails if the fusing unit is not installed or the cover is open

SP1-158-002

Abnormal Noise Confirmation: No Unit: Execute

The fusing motor rotates without the heating control.

Fails if the fusing unit is installed or the cover is open

SP1-158-003Abnormal Noise Confirmation: Operation TimeRotates during this time. Initial value: 20 sec.-

SP1-158-004

Abnormal Noise Confirmation: Operation Line Speed

Line speed at the time of rotation

0: 89 mm/s
1: 178 mm/s
2: 212 mm/s *
3: 252 mm/s *

* : Only for MP C407

SP1-158-005

Abnormal Noise Confirmation: Heat Center Target Temp

Temperature setting for SP1-153-001 (Unit: Execute)

Do not change

SP1-158-007

Abnormal Noise Confirmation: Press Target Temp

Temperature setting for SP1-153-001 (Unit: Execute)