1. Remove the ITB unit. (ITB (Image Transfer Belt) Unit)
  2. Remove the guide plate [A]. ( × 2)
  3. Remove the ID sensor [A] with the bracket. ( × 1)
  4. Remove the ID sensor [A]. ( × 4, × 1, × 1)

    • When cleaning the ID sensor, wipe the parts [A] with a damp cloth.
    • Do not wipe it with a dry cloth, or the ID sensor may attract dirt because of static electricity. Let it dry naturally if necessary.