- Prepare and check the following check points before you visit the customer site. For details, ask the @Remote key person.
 
Check points before making @Remote settings
- The setting of SP5-816-201 in the mainframe must be "0".
 - Print the SMC with SP5-990-002 and then check if a device ID2 (SP5-811-003) must be correctly programmed.
- 6 spaces must be put between the 3-digit prefix and the following 8-digit number (e.g. xxx______xxxxxxxx).
 - ID2 (SP5-811-003) and the serial number (SP5-811-001) must be the same (e.g. ID2: A01______23456789 = serial No. A0123456789)
 - Make sure to shut down and reboot the machine once before printing the SMC. Otherwise, the latest settings may not be collected when the SMC is printed.
 
 - The following settings must be correctly programmed.
- Proxy server IP address (SP5-816-063)
 - Proxy server Port number (SP5-816-064)
 - Proxy User ID (SP5-816-065)
 - Proxy Password (SP5-816-066)
 
 - Get a Request Number
 
Execute the @Remote Settings
- Enter the SP mode.
 - Input the Request number which you have obtained from @Remote Center GUI, and then enter [OK] with SP5-816-202.
 - Confirm the Request number, and then click [EXECUTE] with SP5-816-203.
 Check the confirmation result with SP5-816-204.
Value
Meaning
Solution/ Workaround
0
Succeeded
-
3
Communication error (proxy enabled)
Check the network condition.
4
Communication error (proxy disabled)
Check the network condition.
5
Proxy error (authentication error)
Check Proxy user name and password.
6
Communication error
Check the network condition.
8
Other error
See "SP5816-208 Error Codes" below this.
9
Request number confirmation executing
Processing… Please wait.
11
Already registered
-
12
Parameter error
-
20
Dial-up authentication error
* These errors occur only in the modems that support @Remote.
21
Answer tone detection error
22
Carrier detection error
23
Invalid setting value (modem)
24
Low power supply current
25
unplugged modem
26
Busy line
- Make sure that the screen displays the Location Information with SP5-816-205 only when it has been input at the Center GUI.
 - Click [EXECUTE] to execute the registration with SP5-816-206.
 Check the registration result with SP5-816-207.
Value
Meaning
Solution/ Workaround
0
Succeeded
-
1
Request number error
Check the request number again.
2
Already registered
Check the registration status.
3
Communication error (proxy enabled)
Check the network condition.
4
Communication error (proxy disabled)
Check the network condition.
5
Proxy error (Authentication error)
Check Proxy user name and password.
8
Other error
See "SP5-816-208 Error Codes" below this.
9
Request number confirmation executing
Processing… Please wait.
11
Already registered
-
12
Parameter error
-
20
Dial-up authentication error
* These errors occur only in the modems that support @Remote.
21
Answer tone detection error
22
Carrier detection error
23
Invalid setting value (modem)
24
Low power supply current
25
unplugged modem
26
Busy line
- Exit the SP mode.
 
SP5-816-208 Error Codes
Caused by Operation Error, Incorrect Setting
Code  | Meaning  | Solution/ Workaround  | 
|---|---|---|
-12002  | Inquiry, registration attempted without acquiring Request No.  | Obtain a Request Number before attempting the Inquiry or Registration.  | 
-12003  | Attempted registration without execution of a confirmation and no previous registration.  | Perform Confirmation before attempting the Registration.  | 
-12004  | Attempted setting with illegal entries for certification and ID2.  | Check ID2 of the mainframe.  | 
-12005  | @Remote communication is prohibited. The device has an Embedded RC gate-related problem.  | Make sure that "Remote Service" in User Tools is set to "Do not prohibit".  | 
-12006  | A confirmation request was made after the confirmation had been already completed.  | Execute registration.  | 
-12007  | The request number used at registration was different from the one used at confirmation.  | Check Request No.  | 
-12008  | Update certification failed because mainframe was in use.  | Check the mainframe condition. If the mainframe is in use, try again later.  | 
-12009  | The ID2 in the NVRAM does not match the ID2 in the individual certification.  | Check ID2 of the mainframe.  | 
-12010  | The certification area is not initialized.  | Initialize the certification area.  | 
Error Caused by Response from GW URL
Code  | Meaning  | Solution/ Workaround  | 
|---|---|---|
-2385  | Other error  | |
-2387  | Not supported at the Service Center  | |
-2389  | Database out of service  | |
-2390  | Program out of service  | |
-2391  | Two registrations for the same mainframe  | Check the registration condition of the mainframe  | 
-2392  | Parameter error  | |
-2393  | External RCG not managed  | |
-2394  | Mainframe not managed  | |
-2395  | Box ID for external RCG is illegal.  | |
-2396  | Mainframe ID for external RCG is illegal.  | |
-2397  | Incorrect ID2 format  | Check the ID2 of the mainframe.  | 
-2398  | Incorrect request number format  | Check the Request No.  |