As SC285-00 is a logging SC (SC Type C), it is not displayed at once when an error occurs. Though the equipment can be operated, check the SC history and perform a recovery operation if the SC has occurred.
Countermeasure (1): Large drifting
An abnormal value may be contained in the SP where the MUSIC corrected result is saved.
- Execute SP2-180-001 (Line Pos. Adj.: Clear Color Regist.).
- Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
- Check SP2-194-007 (MUSIC Execution Result: Execution Result).
Countermeasure (2): MUSIC pattern density Error
Execute MUSIC and check the result.
- Execute SP3-011-001 (Manual ProCon :Exe : Normal ProCon).
- Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
- Check SP2-194-007 (MUSIC Execution Result: Execution Result).
Countermeasure (3): Image transfer belt/ Image transfer unit defective
- Execute SP2-112-001 (TM/ID Sensor Check: Execute).
- Check SP2-112-010 (TM/ID Sensor Check: Display Result: Front-Center-Rear).
- Normal if the result is "111"
-->Execute other countermeasures. - Vsg adjustment failed if the result is "2xx", "x2x", or "xx2"
-->Execute recovery operation for SC370 - There is a high probability that contaminants, scars, or irregularities may exist on the belt if the result is "3xx", "x3x", or "xx3"
-->Execute the following procedure;
- Remove the ITB unit, and check for abnormalities such as contaminants or scars, and set it after cleaning.
- Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
- Check SP2-194-007 (MUSIC Execution Result: Execution Result).
- If it fails, replace the ITB unit.
- There is a high probability that contaminants or curl may exist on the belt if the result is "5xx", "6xx", "7xx", "8xx", "x5x", "x6x", "x7x", "x8x", "xx5", "xx6", "xx7", or "xx8".
--> Execute the following procedure
- Remove the ITB unit, and check for abnormalities such as contaminants or scars, and set it after cleaning.
- Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
- Check SP2-194-007 (MUSIC Execution Result: Execution Result).
- If it fails, replace the ITB unit.
- Normal if the result is "111"
Countermeasure (4): ID sensor defective
Follow the next step if executing SP2-111-004 (Forced Line Position: Adj. Mode d) and SP2-194-007 (MUSIC Execution Result: Execution Result) fails.
- Clean the ID Sensor.
- Check the harness and connector for ID sensor.
- Replace the ID sensor.
- Replace the BiCU.
Countermeasure (5): ID Sensor Shutter Defective
Check if there is no problem concerning the mechanism (interference or deformation).
- Execute SP5-804-021 (OUTPUT Check: TM sensor Shutter Solenoid) to operate the ID sensor shutter solenoid to check opening/closing of the shutter.
- Check for a broken harness or connector disconnection.
- If the problem cannot be solved, replace the BiCU.