Callout

Item

Callout

Item

[A]

Toner Transport Coil (Upper)

[D]

Development Roller (Sleeve Architecture)

[B]

Toner Transport Coil (Lower)

[E]

OPC Drum

[C]

Toner Density Sensor (Sensor)

[F]

Doctor Blade

Callout

Item

Callout

Item

[A]

Toner Transport Coil (Upper)

[C]

Toner Density Sensor (mu () Sensor)

[B]

Toner Transport Coil (Lower)

  
  • Developer Agitation Mechanism
    The developer is agitated by the upper [A] and lower [B] transport coils.
    Toner and developer are regulated by the doctor blade, and applied to the development roller.
  • Toner Density Detection Mechanism
    Toner density sensor [C] detects the toner density. Toner is supplied when the toner density is not sufficient.
  • Toner Density Control