Callout | Item | Callout | Item |
---|---|---|---|
[A] | Stay | [D] | Fusing Sleeve Belt (Diameter: 25) |
[B] | Fusing Lamp | [E] | Nip Pad |
[C] | Reflector | [F] | Pressure Roller (Diameter: 25 |
The fusing unit uses the QSU system. (QSU: Quick Start Up).
The heat from the fusing lamp [B] is reflected by the reflector [C] and heats the fusing sleeve belt [D].
The temperature at both ends of the fusing lamp is lower than the middle.
The fusing sleeve belt itself has no drive mechanism; the pressure roller drives it. The nip pad [E] at the sleeve belt side is pushed against the pressure roller and keeps the nip width on the sleeve belt.