Problem:

Under the usage environment of this machine, at the placement location, fluorescent and/or LED lamps flicker.

Causes:

This is a result of the voltage drop that occurs when power is applied to the fusing lamp. It depends on the electrical power environment at the customer's location.

Solutions:

The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the procedure that matches the timing.

Occurrence Timing:

TimingSolutionsSide Effect

Recovery from energy saving

Set SP1-135-001 (Inrush Control) to "1 (ON)."

Recovery time from energy saving becomes slower approx. 0.4 sec.

After the recovery from energy saving

Set SP1-135-001 (Inrush Control) to "1 (ON)."

Set SP1-190-001 (Flicker Control) to "1 (ON)."

• Recovery time from energy saving becomes slower approx. 0.4 sec..

• If the adhesion amount of an image is large, an offset may occur.

• If a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed

PrintingSet SP1-190-001 (Flicker Control) to "1 (ON)".

• If the adhesion amount of an image is large, an offset may occur.

• If a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed.

 Related SP to Fusing Offsets

SP NameSP No.Value
Print Target Temp.:Plain1:FC:CenterSP1-105-001As initial values + 10 °C are the upper limits, change values to improve offsets.   
Print Target Temp.:Plain1:BW:CenterSP1-105-003
Print Target Temp.:Plain2:FC:CenterSP1-105-005
Print Target Temp.:Plain2:BW:CenterSP1-105-007
Print Target Temp.:Thin:FC:CenterSP1-105-009
Print Target Temp.:Thin:BW:CenterSP1-105-011
Print Target Temp.:M-thick:FC:CenterSP1-105-013
Print Target Temp.:M-thick:BW:CenterSP1-105-015