Problem:
Under the usage environment of this machine, at the placement location, fluorescent and/or LED lamps flicker.
Causes:
This is a result of the voltage drop that occurs when power is applied to the fusing lamp. It depends on the electrical power environment at the customer's location.
Solutions:
The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the procedure that matches the timing.
Occurrence Timing:
| Timing | Solutions | Side Effect | 
|---|---|---|
Recovery from energy saving  | Set SP1-135-001 (Inrush Control) to "1 (ON)."  | Recovery time from energy saving becomes slower approx. 0.4 sec.  | 
Set SP1-135-001 (Inrush Control) to "1 (ON)." Set SP1-190-001 (Flicker Control) to "1 (ON)."  | • Recovery time from energy saving becomes slower approx. 0.4 sec.. • If the adhesion amount of an image is large, an offset may occur. • If a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed  | |
| Set SP1-190-001 (Flicker Control) to "1 (ON)". | • If the adhesion amount of an image is large, an offset may occur. • If a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed.  | 
Related SP to Fusing Offsets
| SP Name | SP No. | Value | 
|---|---|---|
| Print Target Temp.:Plain1:FC:Center | SP1-105-001 | As initial values + 10 °C are the upper limits, change values to improve offsets. | 
| Print Target Temp.:Plain1:BW:Center | SP1-105-003 | |
| Print Target Temp.:Plain2:FC:Center | SP1-105-005 | |
| Print Target Temp.:Plain2:BW:Center | SP1-105-007 | |
| Print Target Temp.:Thin:FC:Center | SP1-105-009 | |
| Print Target Temp.:Thin:BW:Center | SP1-105-011 | |
| Print Target Temp.:M-thick:FC:Center | SP1-105-013 | |
| Print Target Temp.:M-thick:BW:Center | SP1-105-015 |