Image Area
[1]: Feed direction, [2]: Image area
Make sure that the registration is adjusted within the adjustment standard range.
After doing the registration adjustment, do the Erase Margin Adjustment in the next section.
Adjustment standard
- Leading edge (sub-scan direction):
B = 3.25 ± 2.75 mm - Trailing edge (sub-scan direction):
D = 3.25 ± 2.75 mm - Side to side (main-scan direction):
A = C = 2.25 ± 1.75 mm