Displayed number shows results of each color sensor check.
00000000 = YYCCMMKK
SP3-012-001 to -010 (Process Control Execute Result)
No.  | Result  | Description  | Possible Causes/Action  | 
|---|---|---|---|
11  | Successfully completed  | Process control self-check successfully completed.  | Check the Vsg adjustment. See the "Vsg Adjustment Result" following this table.  | 
41  | Vt error  | Vt maximum or minimum error is detected.  | 
 Vt maximum error and an image is faint: 
 Vt maximum error and an image is O.K: 
 Vt minimum error: 
  | 
53  | ID sensor coefficient (K5) detection error  | Not enough data can be sampled.  | 
 
 
 
 
 
  | 
54  | ID sensor coefficient (K5) maximum/ minimum error  | When the K5 is more than the value of SP3-362-003 or less than the value of SP3-362-004, the error 54 is displayed.  | 
 Same as 53  | 
55  | Gamma error: Maximum  | Gamma is out of range. 5.0 < Gamma  | 
 Same as 53  | 
56  | Gamma error: Minimum  | Gamma is out of range. Gamma < 0.15  | 
 
  | 
57  | Vk error: Maximum  | Vk is out of range. 150 < Vk  | 
 Same as 53  | 
58  | Vk error: Minimum  | Vk is out of range. Vk < –150  | 
 Same as 53  | 
59  | Sampling data error during gamma correction  | Not enough data can be sampled during the gamma correction.  | 
 Same as 53  | 
99  | Unexpected error  | Process control fails.  | 
 Check the power source.  |