Before Replacing the ITB Unit
Before replacing the ITB unit, reset the PM counter.
- Turn the power ON.
 - Reset the PM counter. (Refer to Replacement Procedure of the PM/Yield Parts)
 - Turn the power OFF.
 
Replacing the ITB Unit
- Remove all the PCDUs (PCDU (Photo Conductor and Development Unit))
 - Remove the fusing unit. (Fusing Unit)
 - Remove the tension spring cover [A]. (
× 1)
 - Release the tension spring [A]. (
× 1)
 - Release the tension belt [A]. (
× 1)
 Put a sheet of paper [A] on the duplex unit with the short edge of the paper pointing towards the ITB unit.
- This is to protect the paper transfer unit from toner when removing the ITB unit.
 
- Remove the ITB unit securing bracket [A]. (
× 1)
 - Pull out the ITB unit [A].