SP-3-014-001 (Developer Initialization Result)
No.  | Result  | Description  | Possible Causes/Action  | 
|---|---|---|---|
1  | Successfully completed  | Developer initialization is successfully completed.  | -  | 
2  | Forced termination  | Developer initialization was forcibly terminated.  | 
 
  | 
6  | Vt error  | Vt is more than 0.7V when Vcnt is 4.3V.  | 
  | 
7  | Vcnt error 1  | Vcnt is less than 4.7V when Vcnt is Vt target ±0.2V.  | 
  | 
8  | Vcnt error 2  | Vt is more than 0.7V when Vcnt is 4.3V and Vcnt is less than 4.7V when Vcnt is Vt target ±0.2V.  | 
  | 
9  | Vcnt error 3  | Vcnt is less than 4.7V.  | 
  | 
- The machine starts developer initialization after you set "Enable" in SP3-902-005, 006, 007, or 008. Developer initialization automatically resumes when you open and close the front door or turn the main switch off and on if an error other than Error 8 occurs.