• The PCDU (K) for MP C307 is different from the one for MP C407. Make sure that you use the correct part number when ordering a PCDU (K).

  1. Remove the waste toner bottle. (Waste Toner Bottle)
  2. Only when removing the PCDU (K), release the ITB contact lever [A].

    • This step is not required for removing the PCDU (CMY).

  3. Check that the ITB has no tension before removing the PCDU. Otherwise, the ITB may be damaged. To release the tension of the ITB, turn the ITB contact cam's screw [A] counterclockwise, until the flat part of the half moon on the screw points to the right.

  4. Remove the PCDU [A] ( × 2, × 1, × 1)

    • Before putting the PCDU back in the machine, check that the ITB has no tension. See step 3 for how to do this.

  5. Put the removed PCDU on a flat surface with a sheet of paper under it.

    • After replacing the PCDU, set the ITB contact lever released in step 2.
    • A new unit detection mechanism for the PCDU clears the PM counters automatically.
    • After replacing the PCDU, do the skew adjustment manually. See “Color Skew Adjustment”.