After Executing SP2-111-003
- Result: "1" in SP2-194-007
- Result: "2" or "3" (Line pattern detection failure) in SP2-194-010, -011, -012
Test pattern check | Possible cause/Countermeasure |
---|
White image, Abnormal image, Low density | - Defective image processing unit
- Low density of test pattern
- Defective BiCU
|
- Replace the high voltage power supply unit.
- Do the forced process control (SP3-011-001) or supply some toner (SP3-030-xxx).
- Replace the BiCU.
|
Normal image, but with color registration errors | - Defective ID sensor shutter
- Defective ID sensor
- Defective BiCU
|
- Replace the ID sensor shutter solenoid.
- Replace the ID sensor.
- Replace the BiCU.
|
After Executing SP2-111-003
- Result: "1" in SP2-194-007
- One of results: "5" (Out of adjustable range) in SP2-194-010, -011, -012, -013
Test pattern check | Possible cause/Countermeasure |
---|
The main scan registrations of M, C, Y, K are shifted by more than ±15. | - Defective laser unit
- Defective BiCU
|
- Perform the color skew adjustment (Image Adjustment).
- Replace the laser unit.
- Replace the BiCU.
|
The sub scan registrations of M, C, Y, K are shifted by more than ±20. | - Defective image transfer belt
- Defective drive units
- Defective BiCU
|
- Replace the image transfer belt.
- Replace the drum motor.
- Replace the BiCU.
|
The main scan registration is shifted by more than ±0.66 mm, but only at the central area of the image on the output. | - Defective ID sensor at center
- Deformed center area on the image transfer belt
- Defective BiCU
|
- Replace the ID sensor.
- Replace the image transfer belt.
- Replace the BiCU.
|
The skew for M, C, Y, K is more than ±0.75 mm. | - Defective PCDU
- Defective laser optics housing unit
- Defective BiCU
|
- Perform the color skew adjustment (Image Adjustment).
- Reinstall or replace the PCDU.
- Replace the laser optics housing unit.
- Replace the BiCU.
|
Others | - Skew correction upper limit error
- Defective BiCU
- Defective laser optics housing unit
|
- Perform the color skew adjustment (Image Adjustment).
- Replace the BiCU.
- Replace the laser optics housing unit.
|
After Executing SP2-111-003
- Result: "1" in SP2-194-007
- Result: "0" in SP2-194-010, -011, -012, -013
Test pattern check | Possible cause/Countermeasure |
---|
| Do SP2-111-001 or -002. |
After Executing SP2-111-001
- Result: "1" in SP2-194-007
- Result: "2" or "3" (Line pattern detection failure) in SP2-194-010, -011, -012, -013
Test pattern check | Possible cause/Countermeasure |
---|
White image, Abnormal image, Low density | - Defective laser optics housing unit shutter
- Defective image processing unit
- Low density of test pattern
- Defective BiCU
|
- Replace the shutter motor.
- Replace the high voltage power supply unit.
- Do the forced process control (SP3-011-001) or supply some toner (SP3-030-xxx).
- Replace the BiCU.
|
Normal image, but with color registration errors | - Defective ID sensor shutter
- Defective ID sensor
- Defective BiCU
|
- Replace the ID sensor shutter solenoid.
- Replace the ID sensor.
- Replace the BiCU.
|
After Executing SP2-111-001
- Result: "1" in SP2-194-007
- Result: "5" (Out of adjustable range) in SP2-194-010, -011, -012
Test pattern check | Possible cause/Countermeasure |
---|
Low image density on the output | |
Do the forced process control (SP3-011-001) or supply some toner (SP3-030-xxx). |
The main scan registrations of M, C, Y, K are shifted by more than ±1.4. | - No defective component
- Defective laser optics housing unit
- Defective BiCU
|
- Do SP2-111-003 again.
- Replace the laser optics housing unit.
- Replace the BiCU.
|
The sub scan registrations of M, C, Y are shifted by more than ±1.4mm from the sub scan registration of K. | - No defective component
- Defective image transfer belt
- Defective drive units
- Defective BiCU
|
- Do SP2-111-003 again.
- Replace the image transfer belt.
- Replace the drum motor.
- Replace the BiCU.
|
The main scan registration is shifted by more than ±0.66 mm, but only at the central area of the image on the output. | - Defective ID sensor at center
- Deformed center area on the image transfer belt
- Defective BiCU
|
- Replace the ID sensor.
- Replace the image transfer belt.
- Replace the BiCU.
|
The skew for M, C, Y, K is more than ± 0.75 mm at the end of the scan line? | - Defective PCDU
- Defective laser optics housing unit
- Defective BiCU
|
- Perform the color skew adjustment (Image Adjustment).
- Reinstall or replace the PCDU.
- Replace the laser optics housing unit.
- Replace the BiCU.
|
Others | - Skew correction upper limit error
- Defective BiCU
- Defective laser optics housing unit
|
- Replace the BiCU.
- Perform the color skew adjustment (Image Adjustment).
- Replace the laser optics housing unit.
|
After Executing SP2-111-001
- Result: "0" in SP2-194-007
- Result: Color registration errors in SP2-194-010, -011, -012, -013
Test pattern check | Possible cause/Countermeasure |
---|
Low image density on the output | |
Do the forced process control (SP3-011-001) or supply some toner (SP3-030-xxx). |
The main scan registration is shifted, but only at the central area of the image on the output. | - Defective ID sensor at center
- Deformed center area on the image transfer belt
- Defective BiCU
|
- Replace the ID sensor.
- Replace the image transfer belt.
- Replace the BiCU.
|
The main scan registrations of M, C, Y, K are shifted. | - Defective laser optics housing unit
- Defective ID sensor
- Defective BiCU
- Incorrect SP value
|
- Perform the color skew adjustment (Image Adjustment).
- Replace the laser optics housing unit.
- Replace the ID sensor.
- Replace the BiCU.
- Adjust the value with SP2-182-004 to -021.
|
The sub scan registrations of M, C, Y, K are shifted. | - Defective image transfer belt
- Defective drive units
- Defective ID sensor
- Defective BiCU
- Incorrect SP value
|
- Replace the image transfer belt.
- Replace the ID sensor.
- Replace the drum motor.
- Replace the BiCU.
- Adjust the value with SP2-182-022 to -039.
|
The skew of M, C, Y, K is different. | - Defective PCDU
- Defective laser optics housing unit
- Defective BiCU
|
- Reinstall or replace the PCDU.
- Perform the color skew adjustment (Image Adjustment).
- Replace the laser optics housing unit.
- Replace the BiCU.
|
The sub scan lines are shifted. Shifted lines appear cyclically. | - Defective PCDU
- Defective drive unit
- Drum phase adjustment error
|
- Reinstall or replace the PCDU.
- Check or replace the drive unit.
|