Use A4/LT paper to make a temporary test chart as shown above.

  1. Put the temporary test chart on the ADF. Then make a copy from one of the feed stations.
  2. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
    Standard: 4.2 ± 2.0 mm for the leading edge registration, 2.0 ± 1.0 mm for the side-to-side registration. The following diagram shows how the image is affected when you adjust in the + or -. direction.

    1: Feed direction

    SP Code

    What It Does

    Adjustment Range

    SP6-006-001

    Side-to-Side Regist: Face

    ± 3.0 mm

    SP6-006-002

    Side-to-Side Regist (1-pass): Back

    ± 2.0 mm

    SP6-006-010

    Leading Edge Regist (1-pass): Face

    ± 5.0 mm

    SP6-006-011

    Leading Edge Regist (1-pass): Back