Use A4/LT paper to make a temporary test chart as shown above.
- Put the temporary test chart on the ADF. Then make a copy from one of the feed stations.
Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
Standard: 4.2 ± 2.0 mm for the leading edge registration, 2.0 ± 1.0 mm for the side-to-side registration. The following diagram shows how the image is affected when you adjust in the + or -. direction.1: Feed direction
SP Code
What It Does
Adjustment Range
SP6-006-001
Side-to-Side Regist: Face
± 3.0 mm
SP6-006-002
Side-to-Side Regist (1-pass): Back
± 2.0 mm
SP6-006-010
Leading Edge Regist (1-pass): Face
± 5.0 mm
SP6-006-011
Leading Edge Regist (1-pass): Back
± 5.0 mm