Do the following after replacing the ITB unit.
- Enter the SP mode.
- Set SP1-001-031 (Leading Edge Registration Std. Measure: On/Off) to “1”.
- Execute SP2-111-004 (Forced Line Position Adj. Mode d).
- SP values from SP1-001-033 to 040 (Leading Edge Registration Offset Standard: 1 to 8) are updated by the above steps.
- Reset SP1-001-031 to “0”.
- Exit from the SP mode.
- Turn the main power off and on.