Make sure that the FFC of the carriage is correctly connected and routed referring to the following points.

  • The FFC [A] must be connected straight, and not at an angle.

  • Never connect the FFC to the carriage connector at an angle. Otherwise, the BiCU or the SBU may be damaged.

  • The FFC must not be sagging and must not drag on the bottom of the scanner unit [B].
  • The FFC must be hooked at part [A] of the carriage.