1. Enter the SP mode.
  2. Output the SMC log data using one of the following ways:
    a) Execute SP5-990-001 to print SMC log data.
    b) Execute SP5-992-001 to save SMC log data to an SD card. (Refer to "SMC List Card Save Function")

    You can print out the PM counter list as follows.

    1. In the SP mode menu, press [PM Counter / New Unit Set].

    2. Press [Counterlist print out].

    3.Press [EXECUTE] to output the PM counter list.

    4. Press [Exit].

  3. In the SMC data, check the values of the counters in SP7-621-002 to 208, to determine what parts should be replaced. (Refer to the SP table in the appendix.)

  4. Set the following SPs (New Unit Detection) to "1" to reset the PM counter.

    Item

    SP

    Fusing sleeve belt assembly

    SP3-701-116

    Pressure roller

    SP3-701-118

    ITB unit

    SP3-701-093

    Paper transfer roller unit

    SP3-701-109

    Waste toner bottle
    (When the bottle is replaced BEFORE a waste toner full or near-full message appears)

    SP3-701-142

    Tray paper feedFeed roller:SP3-701-147
    Friction pad: SP3-701-148
    Bypass feed rollerSP3-701-169

    ADF

    Friction pad: SP3-701-206
    Pickup roller: SP3-701-207
    Feed roller: SP3-701-208

    Toner transport sectionK: SP3-701-220
    C: SP3-701-221
    M: SP3-701-222
    Y: SP3-701-223

    The PCDU and fusing unit detect a new unit automatically.

  5. Turn OFF the main power, and unplug the power cord.
  6. Replace the PM parts and turn ON the power.
    The machine will reset the PM counters automatically. In the case of the development unit, developer initialization will also be done automatically.
  7. Exit the SP mode.