- Enter the SP mode.
Output the SMC log data using one of the following ways:
a) Execute SP5-990-001 to print SMC log data.
b) Execute SP5-992-001 to save SMC log data to an SD card. (Refer to "SMC List Card Save Function")You can print out the PM counter list as follows.
1. In the SP mode menu, press [PM Counter / New Unit Set].
2. Press [Counterlist print out].
3.Press [EXECUTE] to output the PM counter list.
4. Press [Exit].
In the SMC data, check the values of the counters in SP7-621-002 to 208, to determine what parts should be replaced. (Refer to the SP table in the appendix.)
Set the following SPs (New Unit Detection) to "1" to reset the PM counter.
Item
SP
Fusing sleeve belt assembly
SP3-701-116
Pressure roller
SP3-701-118
ITB unit
SP3-701-093
Paper transfer roller unit
SP3-701-109
Waste toner bottle
(When the bottle is replaced BEFORE a waste toner full or near-full message appears)SP3-701-142
Tray paper feed Feed roller:SP3-701-147
Friction pad: SP3-701-148Bypass feed roller SP3-701-169 ADF
Friction pad: SP3-701-206
Pickup roller: SP3-701-207
Feed roller: SP3-701-208Toner transport section K: SP3-701-220
C: SP3-701-221
M: SP3-701-222
Y: SP3-701-223The PCDU and fusing unit detect a new unit automatically.
- Turn OFF the main power, and unplug the power cord.
- Replace the PM parts and turn ON the power.
The machine will reset the PM counters automatically. In the case of the development unit, developer initialization will also be done automatically. - Exit the SP mode.