FU1 | Microfuse | Overcurrent protection for DF Clutch | Symptom - DF Unit does not turn on.
Cause - There is a short in the Controller Board, or a fuse blows caused by a GND short in the harness.
Action - Replace the Controller Board.
|
FU2 | Microfuse | Overcurrent protection for Controller Board | Symptom Cause Action - Replace the Controller Board.
|
FU3 | Microfuse | Overcurrent protection for Scanner CIS LED. | Symptom - Scanner Unit does not turn on.
Cause Action - Replace the Controller Board.
|
FU5 | Microfuse | Overcurrent protection for DF CIS LED. | Symptom - DF Unit does not turn on.
Cause - There is a short in the Controller Board, or a fuse blows caused by a GND short in the harness.
Action - Replace the Controller Board.
|
FU8 | Microfuse | Overcurrent protection for OPU. | Symptom Cause - There is a short in the Controller Board, or a fuse blows caused by a GND short in the harness.
Action - Replace the Controller Board.
|
FU10 | Microfuse | Overcurrent protection for DF & Scanner CIS power. | Symptom - DF Unit and Scanner Unit do not turn on.
Cause - There is a short in the Controller Board, or a fuse blows caused by a GND short in the harness.
Action - Replace the Controller Board.
|
| | | |