SC NO. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC230-01 SC230-02 SC230-03 SC230-04 | D | FGATE*1: Does not turn ON.(01: Bk, 02: C, 03: M, 04: Y) |
GPIO*2 has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGATE assert time. | ||
| ||
|
(*1)FGATE: Signals used between the controller and the engine in order to send the information about the sub scan length of the page to be printed.
(*2)GPIO: A type of input/output terminal
SC NO. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC231-01 SC231-02 SC231-03 SC231-04 | D | FGATE*1: Does not turn OFF.(01: Bk, 02: C, 03: M, 04: Y) |
GPIO*2 has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time. * This is an I/O pin. Such I/O pins can be used for a variety of applications, depending on the setting. | ||
| ||
|
(*1)FGATE: Signals used between the controller and the engine in order to send the information about the sub scan length of the page to be printed.
(*2)GPIO: A type of input/output terminal
SC NO. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC270-00 | D | Write ASIC communication error |
| ||
The unique ID of the write ASIC was not read normally. | ||
|
SC NO. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC277-00 | D | LED Array communication error: power supply system |
The power supply to LED Array has been cut off due to a blown fuse or other problem. | ||
Blown fuse | ||
|
SC NO. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC277-01 SC277-02 SC277-03 SC277-04 | D | LED Array communication error (01: Bk, 02: C, 03: M, 04: Y) |
Communication between the LED head and engine board has failed. | ||
| ||
|