FU101  | Ceramic tube Fuse  | Overcurrent protection for the Fusing Heater circuit  | Symptom Cause - The harness of the Fusing became shorted with GND.
 - Broken Fusing circuit in the PSU
 
 Action  | 
FU102  | Ceramic tube Fuse  | Overcurrent protection for the Power circuit  | Symptom - The power cannot be turned on.
 
 Cause - Varistor 4 has shorted out because of excess voltage, which resulted in excess current flow, causing a FU102 blowout.
 - Primary circuit of the PSU is shorted with GND.
 - Broken the Primary circuit of PSU
 
 Action  | 
FU203  | Microfuse  | Protection for the secondary side Harness of the +24V _LPS output  | Symptom - Engine does not start even though the power of the main body is turned on.
 
 Cause - The overcurrent protection equipment of the PSU suffered a breakdown and the +24V_LPS output became shorted with GND. 
 
 Action  | 
FU204  | Microfuse  | Protection for the secondary side Harness of the +24VS_LPS output  | Symptom - Problems occur, including Process Control error, Jam; an image is not generated; and Toner supply is not carried out.
 
 Cause - The overcurrent protection equipment of the PSU suffered a breakdown and the +24VS_LPS output became shorted with GND.
 
 Action  |