SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC816-00 | [0x0000] | Energy save I/O subsystem error |
SC816-01 | D | Subsystem error |
SC816-02 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-03 | D | Transition to STR was denied. |
SC816-04 | D | Interrupt in kernel communication driver |
SC816-05, 6 | D | Preparation for transition to STR failed. |
SC816-07 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-08 | D | Sysarch (LPUX_ENGINE_TIMERCTRL) error |
SC816-09 | D | Sysarch (LPUX_RETURN_FACTOR_STR) error |
SC816-10 to 12 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-13 | D | open() error |
SC816-14 | D | Memory address error |
SC816-15 to 18 | D | open() error |
SC816-19 | D | Double open() error |
SC816-20 | D | open() error |
SC816-22 | D | Parameter error |
SC816-23, 24 | D | read() error |
SC816-25 | D | write () error |
SC816-26 to 28 | D | write() communication retry error |
SC816-29, 30 | D | read() communication retry error |
SC816-35 | D | read() error |
SC816-36 to 96
| D | Subsystem error |
Energy save I/O subsystem detected some abnormality. | ||
| ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC840-00 | D | EEPROM access error |
| ||
| ||
- |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC841-00 | D | EEPROM read data error |
Mirrored data of the EEPROM is different from the original data in EEPROM. | ||
Data in the EEPROM is overwritten for some reason. | ||
- |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC842-00 | C | Nand-Flash updating verification error |
SCS write error (verify error) occurred at the Nand-Flash module when remote ROM or main ROM was updated. | ||
Nand-Flash defective | ||
Turn the main power off/on. |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC842-50 | C | Number of Nand-Flash defective block exceeded |
At startup, or when recovery from energy saving, the Nand-Flash (eMMC) status was read and the number of defective blocks exceeded the threshold. | ||
- | ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC842-51 | C | Number of Nand-Flash block deletions exceeded |
At startup, or when recovery from energy saving, the Nand-Flash (eMMC) status was read and the number of defective blocks exceeded the threshold. | ||
- | ||
1. Turn the main power off/on. |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC842-52 | D | Nand-Flash (eMMC) data read failure |
The data written to the Nand-Flash (eMMC) cannot be read due to bad sectors. | ||
- | ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC842-53 | D | Nand-Flash CRC error |
CRC error occurs during NandFlash (eMMC) operation. | ||
- | ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC842-54 | D | Nand-Flash CRC error |
During Nand-Flash (eMMC) operation, an access error other than for SC842-52 and SC842-53 is detected. | ||
- | ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC845 | Hardware Error Detected when doing an automatic firmware update | |
SC845-01 | D | Engine Board |
SC845-02 | D | Controller Board |
SC845-03 | D | Operation Panel (Normal) |
SC845-04 | D | Operation Panel (Smart Panel) |
SC845-05 | D | FCU function |
When updating the firmware automatically (ARFU), the firmware cannot be read or written normally, and the firmware update cannot be completed even after 3 retries. | ||
Hardware abnormality of the controller board | ||
Replace the controller board. |
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC845 | Hardware Error Detected when the automatic firmware update | |
SC845-51 | C | Network error, DIMM error (For the MF models only) |
Unzipping the firmware package file downloaded via the ARFU, the application site, or the SFU failed. | ||
| ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC860-50 | D | Storage startup error at main power on (Only for the machine which has the storage device installed) |
An access error occurred at power-on, or no storage device connection. | ||
| ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC860-51 | C | Number of Nand-Flash defective block exceeded (Only for the machine which has the storage device installed) |
At startup, or when recovery from energy saving, the Nand-Flash status was read and the number of defective blocks exceeded the threshold. | ||
Number of defective blocks exceeded threshold for Nand-Flash. | ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC860-52 | C | Number of Nand-Flash block deletions exceeded (Only for the machine which has the storage device installed) |
At startup, or when recovery from energy saving, the Nand-Flash status was read and the number of defective blocks exceeded the threshold. | ||
Number of blocks deleted exceeded threshold for Nand-Flash | ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC861-50 | D | Storage boot failure (Only for the machine which has the storage device installed) |
Access to the storage device fails when recovery from energy saving. | ||
No response from the storage device. | ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC863-50 | D | Storage data read failure (Only for the machine which has the storage device installed) |
The data written to the storage device cannot be read due to bad sectors. | ||
Access destination in the storage device is in a bad sector. | ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC864-50 | D | Storage CRC error (Only for the machine which has the storage device installed) |
CRC error occurs during storage device operation. | ||
Bad sectors were generated during operation. | ||
|
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC865-80 | D | Storage access error (Only for the machine which has the storage device installed) |
An access error occurred when reading/writing the data in the storage device. | ||
During storage device operation, an access error other than those for SC863-50 and SC864-50 is detected. | ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC866-00 | B | SD card authentication error |
A license error was detected for an application that is started from the SD card. | ||
Invalid program data is stored on the SD card. | ||
Store a valid program data on the SD card. |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC867-00 | B | SD card removed |
The SD card was removed while the machine was on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd0). | ||
Turn the main power off/on. |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC867-01 | B | SD card removed |
The SD card was removed while the machine was on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd1). | ||
Turn the main power off/on. |
No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC867-02 | B | SD card removed |
The SD card was removed while the machine was on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd2). | ||
Turn the main power OFF/ON. |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC868-00 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd0) | ||
| ||
|
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer.
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC868-01 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) | ||
| ||
SD card that starts an application
|
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer.
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC868-02 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) | ||
| ||
SD card that starts an application
|
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer.
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC870-00 | B | Address Book data error (Anytime: Address Book Error.) |
SC870-01 | B | Address Book data error (On startup: Media required for storing the Address Book is missing.) |
SC870-02 | B | Address Book data error (On startup: encryption is configured but the module required for encryption (DESS) is missing.) |
SC870-03 | B | Address Book data error (Initialization: Failed to generate a file to store internal Address Book.) |
SC870-04 | B | Address Book data error (Initialization: Failed to generate a file to store delivery sender.) |
SC870-05 | B | Address Book data error (Initialization: Failed to generate a file to store delivery destination.) |
SC870-06 | B | Address Book data error (Initialization: Failed to generate a file to store information required for LDAP search.) |
SC870-07 | B | Address Book data error (Initialization: Failed to initialize entries required for machine operation.) |
SC870-09 | B | Address Book data error (Machine configuration: Inconsistency in the NVRAM area used for storing settings required for Address Book configuration.) |
SC870-10 | B | Address Book data error (Machine configuration: Cannot make a directory for storing the Address Book in the SD/USB FlashROM.) |
SC870-11 | B | Address Book data error (On startup: Inconsistency in Address Book entry number.) |
SC870-20 | B | Address Book data error (File I/O: Failed to initialize file.) |
SC870-21 | B | Address Book data error (File I/O: Failed to generate file.) |
SC870-22 | B | Address Book data error (File I/O: Failed to open file.) |
SC870-23 | B | Address Book data error (File I/O: Failed to write to file.) |
SC870-24 | B | Address Book data error (File I/O: Failed to read file.) |
SC870-25 | B | Address Book data error (File I/O: Failed to check file size.) |
SC870-26 | B | Address Book data error (File I/O: Failed to delete data.) |
SC870-27 | B | Address Book data error (File I/O: Failed to add data.) |
SC870-30 | B | Address Book data error (Search: Failed to obtain data from cache when searching in the machine Address Book. delivery destination/sender.) |
SC870-31 | B | Address Book data error (Search:Failed to obtain data from cache during LDAP search.) |
SC870-32 | B | Address Book data error (Search:Failed to obtain data from cache while searching the WS-Scanner Address Book.) |
SC870-41 | B | Address Book data error (Cache: failed to obtain data from cache.) |
SC870-50 | B | Address Book data error (On startup: Detected abnormality of the Address Book encryption status.) |
SC870-51 | B | Address Book data error (Encryption settings: Failed to create directory required for conversion between plaintext and encrypted text.) |
SC870-52 | B | Address Book data error (Encryption settings: Failed to convert from plaintext to encrypted text.) |
SC870-53 | B | Address Book data error (Encryption settings: Failed to convert from encrypted text to plaintext.) |
SC870-54 | B | Address Book data error (Encryption settings: Detected data inconsistency when reading the encrypted Address Book.) |
SC870-55 | B | Address Book data error (Encryption settings: Failed to delete file when changing encryption setting.) |
SC870-56 | B | Address Book data error (Encryption settings: Failed to erase the file that records the encryption key during an attempt to change the encryption setting.) |
SC870-57 | B | Address Book data error (Encryption settings: Failed to move a file during an attempt to change the encryption setting.) |
SC870-58 | B | Address Book data error (Encryption settings: Failed to delete a directory during an attempt to change the encryption setting.) |
SC870-59 | B | Address Book data error (Encryption settings: Detected a resource shortage during an attempt to change the encryption setting.) |
SC870-60 | B | Address Book data error (Unable to obtain the on/off setting for administrator authentication (06A and later).) |
When an error related to the Address Book is detected during startup or operation. | ||
| ||
Install a device that contains address book information correctly, and turn the main power off/on. If the SC occurs again, do the following steps.
Procedure after SC870 is cleared
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC871-00 | D | FCU error (For the Fax models only) |
An error occurred when FCS detects the fax board and/or controller board defective. | ||
| ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC874-05 | D | Delete all error (Delete data area) : Read error |
SC874-06 | D | Delete all error (Delete data area) : Write error |
SC874-10 | D | Delete all error (Delete data area) : Error in Kernel |
SC874-12 | D | Delete all error (Delete data area) : No designated partition |
SC874-13 | D | Delete all error (Delete data area) : No device file |
SC874-14 | D | Delete all error (Delete data area) : Start option error |
SC874-15 | D | Delete all error (Delete data area) : No designated sector number |
SC874-16 | D | Delete all error (Delete data area) : failure in performing hdderase |
SC874-41 | D | Delete all error (Delete data area) : Other fatal errors |
SC874-42 | D | Delete all error (Delete data area) : End by cancellation |
SC874-61 to -65 | D | Delete all error (Delete data area) : library error |
SC874-66 | D | Delete all error (Delete data area) : Unavailable |
SC874-67 | D | Delete all error (Delete data area) : Erasing not finished |
An error occurred while data was being erased on NVRAM. | ||
| ||
| ||
SC874-68 | D | Delete all error (Delete data area) : MicroSD format failure (Normal) |
SC874-69 | D | Delete all error (Delete data area) : MicroSD format failure (Abnormal) |
|
| An error occurred while data was being erased on MicroSD. |
Error detected in the MicroSD or NVRAM data delete program | ||
Turn the main power switch off and back on, and then execute "Erase All Memory" under UP mode again. (However, if there is a defective sector or other problem with the controller board, the error will persist even after trying the above.) | ||
SC874-70 | D | Delete all error (Delete data area) : Unauthorized library |
SC874-99 | D | Delete all error (Delete data area) : other errors |
An error occurred while data was being erased on NVRAM. | ||
| ||
|
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC875-01 | D | Delete all error (MicroSD erasure) (Data Deletion failure) |
SC875-02 | D | Delete all error (MicroSD erasure) (Data deletion failure) |
An error was detected before MicroSD/data erasure starts. (Failed to erase data/failed to logically format MicroSD) | ||
The modules failed to erase data. | ||
Turn the main power off/on. |
SC No. | Pattern | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
SC899-00 | D | Software performance error (signal reception end) |
Unknown software error occurred. | ||
Occurs when an internal program behaves abnormally. | ||
In the case of a hardware defect
In the case of a software error
|