The Fiery Clone Tool allows you to clone the entire Fiery system to an image file and save it in a folder on a USB flash drive connected to the E-24B. You can restore the image file to the same E-24B (with same key chip) in order to restore the system to a previous configuration.

The Fiery Clone Tool functions with the service switches and the diagnostic LEDs of the rear panel of the E-24B to communicate the status, error, progress and actions required. The service switches are used to apply an action. The diagnostic LEDs flash codes in one second intervals to prompt required actions and to indicate progress and completion of a process, and in half-second intervals to indicate error statuses.

Service switch position

LED status code

Description

Boot

AA, 00

  • To boot the E-24B from the USB flash drive.
  • The diagnostic LEDs flash "AA" then "00" and repeats to indicate boot status.

  • This setting must be performed before you start and using the Fiery Clone Tool.

Backup

b0

  • To back up the E-24B by creating an image file.
  • When you start the backup process, the diagnostic LEDs flash "b1", "b2", "b3" in one second intervals, and repeats the cycle to indicate backup is in progress.
  • When the backup process is complete, the diagnostic LEDs cycle "bC", "00" in one second intervals and repeats to indicate completion status. Remove the USB flash drive at backup completion.

Restore

C0

  • To restore the E-24B with the image file.
  • When you start the restore process, the diagnostic LEDs flash "C1", "C2", "C3" in one second intervals, and repeats the cycle to indicate restore is in progress.
  • When the restore process is complete, the diagnostic LEDs cycle "CC", "00" in one second intervals and repeats to indicate completion status. Remove the USB flash drive at restore completion.