To minimize the impact on the E-24B performance, schedule the backups so that it is run when the E-24B is Idle. The files from the automatic backup are saved on the internal HDD and can be accessed only through Fiery System Restore. Only one automatic backup file is retained (each new automatic backup overwrites the previous backup.).
- Ensure that the E-24B remains powered up during the scheduled backup times, allowing enough time for the backup to complete.
- Enter the IP address of the E-24B into the web browser.
- Confirm the E-24B is in Idle.
- From the Home tab in WebTools, select Schedule Automatic Backup under Fiery System Restore.
- If you are prompted to log in, enter “admin” in the first line, and then the password (Default password is "Fiery.1").
- Select Enable automatic backup.
- Select the desired day and time for the backup and click Save.
- Make sure to schedule the backups when the E-24B will not be in use, for example, midnights and weekends. If the system updates is enabled and scheduled, make sure to schedule the system backups at least two hours before the system updates.