1. Make sure that the power cord of the copier is connected to a power outlet and turn ON the copier main power switch.
  2. Enter SP mode.
  3. Change the setting of SP5193-001 from "0" to "1".
  4. Change the setting of SP5895-001 from "0" to "1".
  5. Turn OFF the copier main power switch and wait until the main power indicator is off.
  6. Turn ON the copier main power switch.

    • The copier must be turned ON before you turn ON the E-24B.
    • Make sure that all firmware modules for the copier are updated to the newest versions. If they are not, update them before you turn ON the E-24B. (Copier Service Manual)

  7. Turn ON the main power switch on the E-24B rear panel.
  8. Press and release the soft power push button on the front panel of the E-24B.
  9. Confirm that the diagnostic LED on the rear panel is lit and showing some digits.
  10. Wait for 10-15 minutes. When the diagnostic LEDs remain at '00', go to the copier operation panel and press the Home button.

    • During the 10-15 minutes, the diagnostic LED may remain displaying 'FF' for several times, but this does not indicate an error.

  11. Touch the Fiery icon. "Please Wait!" may be shown on the copier operation panel for a while.
  12. Within a few minutes, the language selection screen is shown. (If this screen is not shown, then press the Home button on the operation panel of the copier and then touch the Fiery icon again.)
  13. Select the desired language button, and touch the "Continue" button.
    • Simplified Chinese
    • Czech
    • Dutch
    • English
    • French
    • German
    • Italian
    • Polish
    • Brazilian Portuguese
    • Russian
    • Spanish
    • Turkish
    • Korean
    • Traditional Chinese

    If the desired language is not displayed, switch screens using the buttons.

    The default settings for the E-24B depend on the language selection as follows:
     

    Selected Language & Measurement Unit

     

    English - US

    English - Metric / Simplified Chinese / Czech / Dutch / French / German / Italian / Polish / Brazilian Portuguese / Russian / Spanish / Turkish / Korean / Traditional Chinese

    PS Setting

    Default Paper Sizes

    US

    Metric

    PCL Setting

    Paper Size

    Letter

    A4

    Paper Size System Pages

    US

    Metric

    If you selected "English" at the language selection screen, you are prompted to select the Measurement Units. Select either "US" or "Metric", and then touch the "Continue" button.
  14. The System will reboot. Press the Home button on the copier operation panel and wait for 5-10 minutes until the Fiery icon appears on the Home screen.

    • During the 5-10 minutes, the diagnostic LED may remain displaying 'FF' for several times, but this does not indicate an error.

  15. Touch the Fiery icon and wait about a few minutes until the Fiery menu screen appears.
  16. To confirm that the reboot was successful, press the Fiery tab.
  17. Now the E-24B can be used with the default settings (minimum setup).

    • The E-24B setup options should be configured later by the site administrator.
    • Make sure that the system date and time, and the time zone have been adjusted before leaving the customer site. The system date, time, and time zone can be adjusted from the Configure menu. [Link to Adjusting the System Date and Time]