Check the following SPs.
- SP3-012-001 to 010 (Front)
 - SP3-012-011 to 020 (Center)
 - SP3-012-021 to 030 (Rear)
 
Category  | Code  | Result name  | Description  | 
|---|---|---|---|
00 and larger  | 00  | Not executed  | Factory default setting(SP default)  | 
10and larger Result (Normal)  | 11  | Succeeded  | -  | 
20 and larger ID Sensor  | 21  | ID Sensor Vsg adjust error  | Out of range from Vsg=4.0±x.x[V/step]  | 
22  | ID Sensor LED Adjust error  | Ifsg>Max  | |
23  | ID Sensor Output error (Positive reflect)  | Vsg_reg<Min(Max)  | |
24  | ID Sensor output error (Diffusion reflect)  | Vsg_dif<Min(Max)  | |
25  | ID Sensor offset Voltage error (Positive reflect)  | Voffset_reg>Max  | |
26  | ID Sensor offset Voltage error (Diffusion reflect)  | Voffset_dif>Max  | |
45 and larger ID Pattern detection  | 45  | ID Pattern extract error  | Cannot detect ID Pattern  | 
50  | Vmin_Bk/K2 error(Max)  | K:Vmin_Bk / CMY:K2>Max  | |
51  | Vmin_Bk/K2 error(Min)  | K:Vmin_Bk / CMY:K2<Min  | |
52  | K5 error (Max)  | K5>Max  | |
53  | K5 error (Min)  | K5<Min  | |
54  | K5 calculated approximate point error  | K5 calculated approximate point <Min  | |
55  | Development gamma error (Max)  | Development gamma >Max  | |
56  | Development gamma error (Min)  | Development gamma <Min  | |
57  | Start developing voltage: Vk error(Max)  | Start developing voltage: Vk>Max  | |
58  | Start developing voltage: Vk error(Min)  | Start developing voltage: Vk<Min  | |
59  | Not enough valid data  | Adhesion amount data for development gamma calculation point is under 2  | |
60 and larger Potential adjustment  | 61  | LD won’t light  | P patter is not written.  | 
62  | Residual potential: Vr error  | Vr>Max  | |
63  | Electrified potential: Vd adjust error  | Vd cannot be adjusted in target range.  | |
64  | Exposure potential: Vpl adjust error  | Vpl cannot be adjusted in target range  | |
90 and larger Result(End)  | 90  | Potential not adjusted  | Potential control method is set as [0:FIX]  | 
99  | Stopped  | Stopped by door open, power off, error. (Set when execute.)  | 
- Execution result example (In order of YMCK from left)
 - Factory default (SP default): [00,00,00,00]
 - Starting adjust: [99,99,99,99]
 - Fail Vsg adjust(Y): [21,99,99,99]
 - Error of Development gamma Max(C): [99,99,55,99]
 - Succeeded: [11,11,11,11]