Process control adjusts the condition of the imaging hardware to maintain a constant image density. Process control is executed at the following times.
Process Control  | Operative Condition  | Related SPs  | |
|---|---|---|---|
1  | PowerON ProCon :Set  | When a certain time has passed after the previous job end (Except when recovering from an SC or jam)  | SP3-530-001 SP3-530-002 SP3-530-003 SP3-530-004 SP3-530-005 SP3-530-006 SP3-530-007 SP3-530-008  | 
2  | JobEnd ProCon:Set  | When the value of the job end counter becomes more than the threshold (At job end)  | SP3-534-001 to 004 SP3-534-011 to 014  | 
3  | Interrupt ProCon :Set  | When the value of the job interrupt counter becomes more than the threshold  | SP3-533-001 to 004 SP3-533-011 to 014  | 
4  | Non-useTime Procon :Set  | When the value of the non-use time counter becomes more than the threshold  | SP3-531-001 to 005  | 
5  | Manual ProCon:Exe  | When SP 3-011 is used  | SP3-011-001 to 006  | 
6  | Toner End Recovery  | After the Toner End Status is cleared (Recovery is NOT done in the near end status)  | -  | 
7  | Initial Developer Setting Process Control  | When the machine detects a new PCU or development unit  | -  |