- Do not remove or adjust the pressure adjusting screws [A] when replacing the pressure roller.
 - The fusing unit is adjusted in the factory to match the hardness of the pressure roller, so that the nip width will be correct.
 - Do not move the pressure roller to another fusing unit.
 
- Remove the fusing sleeve belt unit. (Fusing Sleeve Belt Unit)
 - Remove the pressure roller [A].
 - Apply the grease (FLUOTRIBO MG GREASE) to the rear shaft of the pressure roller at 5-7mm from the cut edge.
 - Apply the grease (FLUOTRIBO MG GREASE) to the front shaft of the pressure roller at 5-7mm from the C-ring notch.