After performing recovery on SC370, execute the following adjustment procedures.
- Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
 - Execute the following SPs and check the results:
- SP2-194-007 (Execution Result)
 - SP2-194-010 (Error Result: C)
 - SP2-194-011 (Error Result: M)
 - SP2-194-012 (Error Result: Y)
Execute result sample
Factory default: 0
Success: 1 
 - Execute SP3-011-001 (Manual ProCon :Exe).
 - Execute the following SPs and check the results.
- SP3-012-001 to 010 (Front)
 - SP3-012-011 to 020 (Center)
 - SP3-012-021 to 030 (Rear)
Execute result sample (In order of YMCK from left)- Factory default:[00,00,00,00]
 - Starting adjust:[99,99,99,99]
 - Fail Vsg adjust(Y):[21,99,99,99]
 - Error of Development gamma Max(C):[99,99,55,99]
 - Succeed:[11,11,11,11]