SC No.  | Type | Error Name/Error Condition/Major Cause/Solution  | 
SC940-01  | D  | Toner supply motor (K) defective  | 
SC940-02  | D  | Toner supply motor (C) defective  | 
SC940-03  | D  | Toner supply motor (M) defective  | 
SC940-04  | D  | Toner supply motor (Y) defective  | 
  | 
  | Toner supply motor connector missing, disconnection Toner supply motor harness get caught. Toner supply motor malfunction, or the driver of the toner supply motor is defective.  | 
  | 
  | 
  | 
SC No.  | Type | Error Name/Error Condition/Major Cause/Solution  | 
SC940-50  | C  | Key counter device defective  | 
  | 
  | When the key counter is ON, the value of the register of the key counter set detection signal is zero three times in a row.  | 
  | 
  | The driver of the key counter device is defective.  | 
  | 
  | Replace the BICU, the imaging IOB (PCB2), or the paper transport IOB (PCB1).  | 
SC No.  | Type | Error Name/Error Condition/Major Cause/Solution  | 
SC940-81  | D  | Load SW1: Overcurrent detection  | 
  | 
  | The load SW has detected and limited overcurrent.  | 
  | 
  | 
  | 
  | 
  | 
  | 
SC No.  | Type | Error Name/Error Condition/Major Cause/Solution  | 
SC940-82  | D  | Load SW2: Overcurrent detection  | 
  | 
  | The load SW has detected and limited overcurrent.  | 
  | 
  | Short-circuit of the following units: 
  | 
  | 
  | 
 If started normally: The 5V IO of an item (harness or electrical component) connected to one of the abovementioned connectors may be short-circuited. To determine which component has failed, press the connectors one at a time and then turn the power off and then back on. Then replace the harness or failed component. If SC-940-82 occurs repeatedly: Replace the paper transport IOB (PCB1).  | 
SC No.  | Type | Error Name/Error Condition/Major Cause/Solution  | 
SC940-83  | D  | Load SW3: Overcurrent detection  | 
  | 
  | The load SW has detected and limited overcurrent.  | 
  | 
  | Short-circuit of the following units: 
  | 
  | 
  | 
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC995-01  | D  | CPM setting error 1  | 
Comparison of machine serial number (11 digits) and machine identification code. Details: 
  | ||
Machine serial number (11 digits) or machine identification code does not match.  | ||
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC995-02  | D  | CPM setting error 2  | 
Comparison of machine serial number (11 digits) and machine identification code. Details: Machine serial number cannot be identified because of NV-RAM replacement or malfunctioning.  | ||
Machine serial number (11 digits) or machine identification code does not match.  | ||
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC995-03  | D  | CPM setting error 3  | 
Comparison of machine serial number (11 digits) and machine identification code. Details: Unable to recognize machine identification code because the controller was replaced incorrectly or is malfunctioning.  | ||
Machine serial number (11 digits) or machine identification code does not match.  | ||
Replace it with a specified controller.  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC995-04  | D  | CPM setting error 4  | 
Comparison of machine serial number (11 digits) and machine identification code.  | ||
Machine serial number (11 digits) or machine identification code does not match.  | ||
Return the parts to the original configuration, and then replace them according to the manual.  |