- Do not touch the rollers but hold the upper/lower resin part [A] when you lift the Image Transfer Unit. Touching the rollers may cause poor image quality.
 
- Remove the Image transfer belt unit. (Image Transfer Belt Unit)
 - Remove the image transfer front cover. (Image Transfer Cleaning Unit)
 - Remove the image transfer upper cover [A].
 - Remove the bracket [A].
 - Remove the brackets [A] [B].
 - Remove the image transfer cleaning unit. (Image Transfer Cleaning Unit)
 - Remove the tension fixing frames [A] and [B] (front side: black, rear side: gray).
 - Holding the resin parts on the top and bottom, position the image transfer unit with the front side underneath.
 - Rotate the gear [A] to change to the OPEN position.
The part in the red circle opens. - Release the tension, and remove the belt.